Heterogeneity of Treatment Effects in an Analysis of Pooled Individual Patient Data From Randomized Trials of Device Closure of Patent Foramen Ovale After Stroke

Authors, Journal, Affiliations, Type, DOI

Overview

The SCOPE consortium analysis, and the paper from which everything about PFO closure selection in this wiki ultimately derives. Six trials, 3,740 patients, individual-level data harmonised across 20 years and six countries — 121 primary events over a median 57 months. It is the strongest evidence in the field and the source of PASCAL.

Its central finding is that the average treatment effect is a fiction. Closure reduced recurrent ischaemic stroke by 59% (adjusted HR 0.41) — an honest and reproducible average — but that average conceals a stratum in which closure does nothing at all and adds atrial fibrillation (PASCAL "unlikely", HR 1.14), and a stratum in which it reduces recurrence by 90% (probable, HR 0.10). The absolute risk reduction is 2.1% at two years in both the "possible" and "probable" categories — an NNT of about 50 — which the authors point out is comparable to antihypertensive, antiplatelet and statin therapy in secondary stroke prevention.

Two results are more interesting than the headline and less often quoted. First, closure reduced PFO-associated recurrent stroke by 76% (HR 0.24) but all-cause ischaemic stroke by only 59% — the difference is the proportion of recurrences that were never going to be prevented by closing a hole. Second, the outcome patients care about most did not reach significance: disability-worsening recurrent stroke, HR 0.59 (0.37–1.22), P=.14, limited by missing functional data.

Keywords

Patent foramen ovale · PFO closure · heterogeneity of treatment effect · RoPE score · PASCAL classification · individual participant data meta-analysis · recurrent ischaemic stroke

Key Takeaways

Design and population

Primary and secondary efficacy outcomes

Outcome Device (per 100 py) Medical (per 100 py) 2-year ARR Adjusted HR (95% CI) P
Recurrent ischaemic stroke 0.47 1.09 1.72% (0.73–2.72) 0.41 (0.28–0.60) <.001
PFO-associated recurrent stroke (adjudicated) 0.24 0.90 2.21% (1.08–3.34) 0.24 (0.14–0.43) <.001
Ischaemic stroke or early all-cause death 0.47 1.09 1.72% 0.41 (0.28–0.60) <.001
+ vascular death 0.55 1.15 1.62% 0.44 (0.31–0.64) <.001
Ischaemic stroke, TIA or vascular death 1.08 1.72 1.61% 0.60 (0.45–0.79) <.001
Disability-worsening recurrent stroke 0.16 0.27 0.18% (−0.39 to 0.75) 0.59 (0.37–1.22) .14

Robustness

Analysis HR (95% CI)
Primary (adjusted) 0.41 (0.28–0.60)
Unadjusted 0.42 (0.29–0.62)
Per protocol 0.37 (0.24–0.57)
As treated 0.40 (0.27–0.59)
Multiple imputation 0.41 (0.26–0.64)
Leave-one-out, minimum (without CLOSURE) 0.32 (0.20–0.51)
Leave-one-out, maximum (without CLOSE-A) 0.45 (0.30–0.66)

Heterogeneity — RoPE

RoPE Device events/n Medical events/n HR (95% CI) 2-year risk, device vs medical ARR NNT
<7 29/700 41/704 0.61 (0.37–1.00) 2.9% vs 4.0% 1.1% (−0.9 to 3.1) 91
≥7 11/1,189 41/1,147 0.21 (0.11–0.42) 0.6% vs 2.6% 2.1% (1.0–3.1) 49

Heterogeneity — PASCAL

High RoPE (≥7) High-risk feature (large shunt >20 bubbles, and/or ASA ≥10 mm) Category HR (95% CI) 2-year risk, device vs medical ARR NNT
No No Unlikely (~15% of patients) 1.14 (0.53–2.46) 4.1% vs 3.4% −0.7% (−4.0 to 2.6) —
No Yes Possible 0.38 (0.22–0.65) 1.5% vs 3.6% 2.1% (0.6–3.6) 47
Yes No Possible 0.38 (0.22–0.65) 1.5% vs 3.6% 2.1% (0.6–3.6) 47
Yes Yes Probable 0.10 (0.03–0.35) 0.3% vs 2.5% 2.1% (0.9–3.4) 47

Safety (as-treated population: 1,762 device, 1,956 no device)

Outcome Device No device Risk difference Relative risk (95% CI) P
Any serious adverse event 506 (28.7%) 516 (26.4%) 1.97% (−0.89 to 4.82) 1.07 (0.97–1.19) .18
Atrial fibrillation, all 88 (5.0%) 21 (1.1%) 3.77% (2.65–4.89) 4.54 (2.78–7.39) <.001
AF beyond 45 days 43 (2.4%) 16 (0.8%) 1.38% (0.56–2.19) 2.60 (1.44–4.70) .001
Major bleeding 25 (1.4%) 33 (1.7%) −0.31% (−1.09 to 0.47) 0.80 (0.47–1.40) .45
Venous thromboembolism 25 (1.4%) 10 (0.5%) 0.87% (0.22–1.51) 2.59 (1.26–5.36) .007

Safety tracks the causal category, in the opposite direction to benefit

Limitations of the document

Key Concepts Mentioned

concepts/Patent-Foramen-Ovale · concepts/PFO-Closure-Selection · concepts/PFO-Detection-and-Anatomy · concepts/Poststroke-AF-Monitoring

Key Entities Mentioned

entities/Ischemic-Stroke · entities/Atrial-Fibrillation

Named but unlinked: RoPE · PASCAL · SCOPE · RESPECT · REDUCE · CLOSE · CLOSURE I · PC Trial · DEFENSE-PFO · Amplatzer PFO Occluder · Gore Cardioform